Methods for assessing the state of concrete in fire damaged structures
 
 
More details
Hide details
1
Politechnika Krakowska, Katedra Technologii Materiałów Budowlanych i Ochrony Budowli
 
 
Publication date: 2009-07-01
 
 
Cement Wapno Beton 14(4) 167-178 (2009)
 
REFERENCES (16)
1.
I. Hager, P. Pimienta, Impact of the polypropylene fi bers on the mechanical properties of HPC concrete, Proceedings of Sixth Rilem Symposium on Fibre Reinforced Concrete (FRC), BEFIB 2004, September 2004, Varenna, Italy.
 
2.
I. Hager, J. Śliwiński, T. Durica, The impact of heating conditions on temperature distribution in high performance concrete specimens of various shapes and sizes.”, Slovak Journal of Civil Engineering, Volume XIV, 2006/2, p. 8-13.
 
3.
I. Hager, P. Pimienta, Mechanical properties of HPC at high temperatures, Proc. Int. Workshop fi b Task Group.
 
4.
I. Hager, Comportement à haute température des bétons à haute performance - évolution des principales propriétés mécaniques, thèse du doctorat, Ecole Nationale des Ponts et Chaussées, listopad 2004.
 
5.
Concrete Structures After Fire, Concrete Construction, March 1972, Vol. 17, No. 3, Concrete Construction Publications, Inc., Addison, IL, 1972, p. 101.
 
6.
Fire design of concrete structures – structural behavior and assessment. State-of-art report prepared by Task Group 4.3, Fire design of concrete structures, FIB - Federation International du Béton, July 2008, p. 209.
 
7.
EN 1992-1-2: Eurocode 2 – Design of concrete structures. Part 1.2: General rules – Structural fi re design, December 2004, p. 97.
 
8.
Présentation des techniques de diagnostic de l’état d’un béton soumis à un incendie, décembre 2005, n° 62, Laboratoire Central des Ponts et Chaussées, Paris, France, p. 114.
 
9.
Assessment and Repair of Fire-Damaged Concrete Structures, Technical Report No . 33, The Concrete Society, London, United Kingdom, 1990.
 
10.
M. Colombo, R. Felicetti, New NDT techniques for the assessment of fi re-damaged concrete structures, Fire Safety Journal, Vol. 42, Issues 6-7, September-October 2007, Pages 461-472.
 
11.
R. Felicetti, The drilling resistance test for the assessment of fi re damaged concrete, Cement and Concrete Composites, Vol. 28, Issue 4, April 2006, Pages 321-329.
 
13.
D. C. K. Tay, C. T. Tam, In situ investigation of the strength of deteriorated concrete, Construction and Building Materials, Vol. 10 (1996), p. 17-26.
 
14.
Internal fracture testing of in-situ concrete: a method of assessing compressive strength, Building Research Establishment, BRE Information paper IP22/80, 1980, p. 4.
 
15.
N. R. Short, J. A. Purkiss, S. E. Guise, Assessment of fi re damaged concrete using color image analysis, Construction and Building Materials, Vol. 15 (2001) p. 9-15.
 
16.
N. R. Short, J. A. Purkiss, S. E. Guise, Assessment of fi re damaged concrete using crack density measurements, Structural Concrete, Vol. 5 (2002), p. 137-143.
 
ISSN:1425-8129
Journals System - logo