The effect of the strengthening of AAC masonry walls using FRCM system
 
More details
Hide details
1
Silesian University of Technology, Department of Building Structures, Akademicka 5, 44-100 Gliwice, Poland
 
2
BUDINŻ PB sp. z o.o. sp. komandytowa, ul. Niedobczycka 2, 44-290, Jejkowice, Poland
 
 
Publication date: 2021-01-18
 
 
Cement Wapno Beton 25(5) 376-389 (2020)
 
KEYWORDS
ABSTRACT
This paper describes results from testing the tensile strength of compressed masonry walls strengthened with fiber-reinforced cement matrix [FRCM] system on one side, both sides, or without any strengthening. Test models were prepared from masonry units made of autoclaved aerated concrete SOLBET OPTIMAL 4/600. Walls were built with a ready-mixed mortar for thin layer joints of class M5, without filling head joints. PBO fibre grids embedded in a mineral matrix were used as superficial strengthening. Lateral surfaces of masonry walls were strengthened with ready-mixed mortar PBO-MX GOLD MASONRY with embedded grid PBO-MESH GOLD 22/22. Then, the surface layer of ready-mix mortar PBO-MX GOLD MASONRY was applied. The used superficial strengthening provided an additional strengthening of the cracked models and their safer behaviour after failure.